<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Spectrophotomètres - Muniatech</title>
	<atom:link href="https://muniatech.com/categorie-produit/instruments-de-laboratoire/spectrophotometres/feed/" rel="self" type="application/rss+xml" />
	<link>https://muniatech.com/categorie-produit/instruments-de-laboratoire/spectrophotometres/</link>
	<description>Performance delivred</description>
	<lastBuildDate>Sun, 08 Jan 2023 12:32:51 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.5</generator>

<image>
	<url>https://muniatech.com/wp-content/uploads/2022/05/cropped-NewIcon-32x32.png</url>
	<title>Spectrophotomètres - Muniatech</title>
	<link>https://muniatech.com/categorie-produit/instruments-de-laboratoire/spectrophotometres/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Spectrophotomètre compact, portable</title>
		<link>https://muniatech.com/produit/spectrophotometre-compact-portable/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 08 Jan 2023 12:32:50 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4146</guid>

					<description><![CDATA[<h2>Description</h2>
<ol>
<li>Beautiful appearance and perfect combination with ergonomic structure design;</li>
<li>Adopt high-life and low-power combined LED light source, including UV/excluding UV;</li>
<li>Φ20mm aperture adapt to larger samples or uneven samples;</li>
<li>Measure sample spectra, accurate Lab data , can be used in color matching and accurate color transmission;</li>
<li>High electronic hardware configuration: 3.5-inch TFT true color screen, capacitive touch screen, concave grating, 256-pixel dual-array CMOS detector, etc.;</li>
<li>USB/Bluetooth 4.0 (compatible with 2.1) dual communication mode, more adaptable;</li>
<li>Super stain-resistant and stable standard white calibration plate;</li>
<li>Large-capacity storage space, can store more than 30,000 test data;</li>
<li>Two standard observers, multiple light source modes, multiple color systems, and a variety of standard colorimetric indicators to meet the needs of various customers for color measurement;</li>
<li>PC software has powerful function extensions;</li>
</ol>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-compact-portable/">Spectrophotomètre compact, portable</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="102">Illumination/Observation system</td>
<td width="451">45/0(45 ring-shaped illumination, vertical viewing);<br />
Comply with CIE No.15，GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7,GB 2893、GB/T 18833</td>
</tr>
<tr>
<td width="102">Integrating Sphere Size</td>
<td width="451">Φ48mm</td>
</tr>
<tr>
<td width="102">Light Source</td>
<td width="451">Combined LED Light, UV Light</td>
</tr>
<tr>
<td width="102">Spectral separation device</td>
<td width="451">Concave Grating</td>
</tr>
<tr>
<td width="102">Detector</td>
<td width="451">256 Image Element Double Array CMOS Image Sensor</td>
</tr>
<tr>
<td width="102">Wavelength Range</td>
<td width="451">400~700nm</td>
</tr>
<tr>
<td width="102">Wavelength Pitch</td>
<td width="451">10nm</td>
</tr>
<tr>
<td width="102">Half Bandwidth</td>
<td width="451">10nm</td>
</tr>
<tr>
<td width="102">Reflectance Range</td>
<td width="451">0~200%</td>
</tr>
<tr>
<td width="102">Measuring Aperture</td>
<td width="451">Φ20mm</td>
</tr>
<tr>
<td width="102">Color Space</td>
<td width="451">CIE LAB,XYZ,Yxy,LCh,CIE LUV，HunterLAB,βxy</td>
</tr>
<tr>
<td width="102">Color Difference Formula</td>
<td width="451">ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00,ΔE（Hunter）</td>
</tr>
<tr>
<td width="102">Other Colorimetric Index</td>
<td width="451">WI(ASTM E313，CIE/ISO,AATCC,Hunter)，<br />
YI(ASTM D1925，ASTM 313),<br />
TI(ASTM E313，CIE/ISO),<br />
MI (Metamerism Index),<br />
Staining Fastness, Color Fastness, Color Strength, Opacity,Supporting Colorimetric Polygon Tolerance</td>
</tr>
<tr>
<td width="102">Observer Angle</td>
<td width="451">2°/10°</td>
</tr>
<tr>
<td width="102">Illuminant</td>
<td width="451">D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4，F5，F6,F7(DLF),F8,F9，F10(TPL5),F11(TL84),F12(TL83/U30)</td>
</tr>
<tr>
<td width="102">Display Data</td>
<td width="451">Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset</td>
</tr>
<tr>
<td width="102">Measurement Time</td>
<td width="451">About 1.5s</td>
</tr>
<tr>
<td width="102">Repeatability</td>
<td width="451">Spectral reflectance: Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%)</p>
<p>Chromaticity value:within ΔE*ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)</td>
</tr>
<tr>
<td width="102">Inter-instrument Error</td>
<td width="451">Within ΔE*ab 0.2 (Average for 12 BCRA Series II color tiles)</td>
</tr>
<tr>
<td width="102">Measurement mode</td>
<td width="451">Single Measurement, Average Measurement(2-99)</td>
</tr>
<tr>
<td width="102">Size(L*W*H)</td>
<td width="451">184 x 77 x 105mm</td>
</tr>
<tr>
<td width="102">Weight</td>
<td width="451">About 600g</td>
</tr>
<tr>
<td width="102">Power source</td>
<td width="451">Li-ion battery. 5000 measurements within 8 hours</td>
</tr>
<tr>
<td width="102">Illuminant Life Span</td>
<td width="451">5 years, more than 3 million times measurements</td>
</tr>
<tr>
<td width="102">Display</td>
<td width="451">3.5-inch TFT color LCD, Capacitive Touch Screen</td>
</tr>
<tr>
<td width="102">Interface</td>
<td width="451">USB, Bluetooth 4.0</td>
</tr>
<tr>
<td width="102">Data memory</td>
<td width="451">Standard 1000 Pcs, Sample 30000 Pcs</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-compact-portable/">Spectrophotomètre compact, portable</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Spectrophotomètre UV/ VIS Microvolume</title>
		<link>https://muniatech.com/produit/spectrophotometre-uv-vis-microvolume/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 08 Jan 2023 12:18:01 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4143</guid>

					<description><![CDATA[<h2>Description</h2>
<p>1. 7-inch high-definition capacitive touch screen, no need for computer connection, and it can be detected by a single machine.<br />
2. Detection wavelength range: 190-850nm<br />
3. Only 0.5—2μL sample is required for base measurement, and dilution is not required even for high concentration samples.<br />
4. It has an OD600 optical path detection system and a cuvette mode, which is convenient for the detection of the concentration of bacteria, microorganisms and other culture solutions.<br />
5. The closing of the detection arm can be detected automatically.<br />
6. It has an extremely fast detection speed and can be detected at any time. The measurement of each sample is completed in a short period of time.<br />
7. The sample does not need to be diluted, and the concentration range of the measurable sample is more than 100 times that of a conventional ultraviolet-visible photometer.<br />
8. Easy-to-use data printing function, print reports directly through the built-in printer.<br />
9. The service life of the xenon flash lamp can reach 1 billion times (up to 10 years). It can be used directly without preheating and can be tested at any time. No other consumables are required.</p>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-uv-vis-microvolume/">Spectrophotomètre UV/ VIS Microvolume</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td colspan="2" width="247"><strong>Model</strong></td>
<td width="155"><strong>SP-MUV1000</strong></td>
<td width="165"><strong>SP-MUV1000F</strong></td>
</tr>
<tr>
<td colspan="2" width="247">Wavelength range</td>
<td width="155">190-850nm</td>
<td width="165">190-850nm</td>
</tr>
<tr>
<td colspan="2" width="247">Sample capacity</td>
<td width="155">0. 5-2μl</td>
<td width="165">0. 5-2μl</td>
</tr>
<tr>
<td colspan="2" width="247">Optical distance</td>
<td width="155">0. 05mmx 0. 2mm、 1.0mm (automatic switchover)</td>
<td width="165">0. 05mmx 0. 2mm、 1.0mm (automatic switchover)</td>
</tr>
<tr>
<td colspan="2" width="247">Light source/life</td>
<td width="155">Xenon lamp/10<sup>9</sup> times</td>
<td width="165">Xenon lamp/10<sup>9</sup> times</td>
</tr>
<tr>
<td colspan="2" width="247">Detector</td>
<td width="155">2048 element linear CCD array</td>
<td width="165">2048 element linear CCD array</td>
</tr>
<tr>
<td colspan="2" width="247">Spectral bandwidth</td>
<td width="155">2nm</td>
<td width="165">2nm</td>
</tr>
<tr>
<td colspan="2" width="247">Absorbed light accuracy</td>
<td width="155">0. 003Abs</td>
<td width="165">0.003Abs</td>
</tr>
<tr>
<td colspan="2" width="247">Absorbance accuracy</td>
<td width="155">±1% (7. 332Abs at 260nm)</td>
<td width="165">±1% (7. 332Abs at 260nm)</td>
</tr>
<tr>
<td colspan="2" width="247">Absorbance range</td>
<td width="155">(Equivalent to 10mm) 0.04-300A</td>
<td width="165">(Equivalent to 10mm) 0.04-300A</td>
</tr>
<tr>
<td colspan="2" width="247">Nucleic acid concentration range</td>
<td width="155">2ng/ μ L dsDNA~15000ng/ μ L dsDNA</td>
<td width="165">2ng/ μ L dsDNA~15000ng/ μ L  dsDNA</td>
</tr>
<tr>
<td colspan="2" width="247">Detection time</td>
<td width="155">≤5 s</td>
<td width="165">≤5 s</td>
</tr>
<tr>
<td colspan="2" width="247">Fluorescence detection</td>
<td width="155">/</td>
<td width="165">Excitation wavelength: 460nmEmission wavelength: 525nm</td>
</tr>
<tr>
<td rowspan="3" width="104">Fluorescence detection</td>
<td width="143">Linearity</td>
<td width="155">/</td>
<td width="165">R<sup>2</sup>&gt;0. 995</td>
</tr>
<tr>
<td width="143">Repeatability</td>
<td width="155">/</td>
<td width="165">&lt;1.5%</td>
</tr>
<tr>
<td width="143">Stability</td>
<td width="155">/</td>
<td width="165">&lt;1.5%</td>
</tr>
<tr>
<td colspan="2" width="247">Print</td>
<td width="155">Built-in thermal printer</td>
<td width="165">Built-in thermal printer</td>
</tr>
<tr>
<td colspan="2" width="247">Data output mode</td>
<td width="155">USB</td>
<td width="165">USB</td>
</tr>
<tr>
<td colspan="2" width="247">Material of sample base</td>
<td width="155">Quartz optical fiber and high hard aluminum</td>
<td width="165">Quartz optical fiber and high hard aluminum</td>
</tr>
<tr>
<td colspan="2" width="247">Input voltage</td>
<td width="155">VAC 100-240V; VDC 24V 2A</td>
<td width="165">VAC 100-240V; VDC 24V 2A</td>
</tr>
<tr>
<td colspan="2" width="247">Power</td>
<td width="155">&lt;15W (Standby: 5W)</td>
<td width="165">&lt;15W (Standby: 5W)</td>
</tr>
<tr>
<td colspan="2" width="247">Dimensions</td>
<td width="155">208*290*180 (WXDXH)</td>
<td width="165">208*290*180(WXDXH)</td>
</tr>
<tr>
<td colspan="2" width="247">Weight</td>
<td width="155">3.2 kg</td>
<td width="165"> 3.2 kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-uv-vis-microvolume/">Spectrophotomètre UV/ VIS Microvolume</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Photomètre de flamme</title>
		<link>https://muniatech.com/produit/photometre-de-flamme/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 08 Jan 2023 11:57:42 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4139</guid>

					<description><![CDATA[<h2>Description</h2>
<p>1. Direct concentration display (Don’t cover FP-I640)<br />
2. Automatic calculation of correlation coefficient (Don’t cover FP-I640)<br />
3. Pre-selection of flame sizes<br />
4. Flameout protection device<br />
5. Measuring range changing<br />
6. Concentration units selectable<br />
7. Multilingual user interface<br />
8. Air compressor provide</p>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/photometre-de-flamme/">Photomètre de flamme</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td colspan="2"><strong>Model</strong></td>
<td><strong>FP-I6450</strong></td>
<td><strong>FP-I6440</strong></td>
<td><strong>FP-I6431</strong></td>
<td><strong>FP-I6430</strong></td>
<td><strong>FP-I6410</strong></td>
<td><strong>FP-I640</strong></td>
</tr>
<tr>
<td colspan="2">Operation mode</td>
<td colspan="6">7- inch color touch- screen</td>
</tr>
<tr>
<td colspan="2">Display value</td>
<td colspan="5">Concentration value</td>
<td>Optical power</td>
</tr>
<tr>
<td colspan="2">Data range</td>
<td colspan="4">0.000～999.9</td>
<td>000.0～999.9</td>
<td>0000～9999</td>
</tr>
<tr>
<td colspan="2">Testable</td>
<td>K, Na, Li, Ca, Ba</td>
<td>K, Na, Li, Ca</td>
<td>K, Na, Ca</td>
<td>K, Na, Li</td>
<td>K, Na</td>
<td>K, Na</td>
</tr>
<tr>
<td colspan="2">Channel Qty.</td>
<td>5</td>
<td>4</td>
<td colspan="2">3</td>
<td colspan="2">2</td>
</tr>
<tr>
<td colspan="2">Response time</td>
<td colspan="6">&lt;8s</td>
</tr>
<tr>
<td colspan="2">Sample uptake</td>
<td colspan="6">&lt;6ml/min</td>
</tr>
<tr>
<td colspan="2">Stability</td>
<td colspan="6">&lt; 3% drift over15s when continuously aspirating.</td>
</tr>
<tr>
<td colspan="2">Reproducibility</td>
<td colspan="6">&lt; 3% coefficient of variation for 7 consecutive samples</td>
</tr>
<tr>
<td colspan="2">Curve Graph</td>
<td colspan="4">Display</td>
<td>○</td>
<td>○</td>
</tr>
<tr>
<td colspan="2">Printer</td>
<td colspan="5">Optional build-in thermal printer</td>
<td>○</td>
</tr>
<tr>
<td colspan="2">COM</td>
<td colspan="5">USB</td>
<td>○</td>
</tr>
<tr>
<td colspan="2">Fuel</td>
<td colspan="6">LPG</td>
</tr>
<tr>
<td colspan="2">Power</td>
<td colspan="6">AC220V±22V 50Hz±1Hz,250W</td>
</tr>
<tr>
<td colspan="2">Packing size</td>
<td colspan="6">570mm×530mm×400mm, 18kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/photometre-de-flamme/">Photomètre de flamme</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Spectrophotomètre à fluorescence</title>
		<link>https://muniatech.com/produit/spectrophotometre-a-fluorescence/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 08 Jan 2023 11:41:59 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4137</guid>

					<description><![CDATA[<h2>Description</h2>
<p>Fluorescence spectrophotometer is a new generation of high-performance molecular luminescence analysis equipment. This product is designed for high performance, with high signal to noise ratio, ultra-high scanning speed, ultra-high resolution, ultra-high wavelength accuracy and a variety of accessories. This instrument easily meets the requirements in material research, drug analysis, biochemical and clinical testing, water quality control, food safety testing and other areas of qualitative and quantitative analysis and scientific research. Quantum yield accessory is available for SP-LF98 fluorescence spectrophotometer.</p>
<p><strong>Main Features:</strong><br />
1. Horizontal slit optical design, with excellent luminous detection efficiency and high signal to noise ratio. Water Raman peak SNR better than 350: 1 (P-P) or 1000: 1 (RMS). The minimum sample volume is 0.5mL when using a standard 10mm square sample cell.<br />
2. Wavelength scanning speed up to 60000 nm / min.<br />
3. Bandwidth 1/2/5/10/20nm adjustable.<br />
4. Fluorescence Quantum Yield accessory available.<br />
5. The software offers fluorescence 3D scanning, equal-wavelength difference synchronous scanning, equal wave number difference (constant energy difference) synchronous scanning functions (Synchronous scanning function require pro version software).<br />
6. Multi accessories available.<br />
7. Using Hamamatsu’s high quality Xenon light source and photoelectric multiplier tube detectors and instruments to provide sufficient light intensity signal and the detection sensitivity.<br />
8. Built-in frequency filter. Built-in optical gate, designed for unstable sample.</p>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-a-fluorescence/">Spectrophotomètre à fluorescence</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="194">Excitation Source</td>
<td width="381">150W xenon lamp（Hamamatsu）</td>
</tr>
<tr>
<td width="194">Excitation Wavelength</td>
<td width="381">200nm~900nm</td>
</tr>
<tr>
<td width="194">Emission Wavelength</td>
<td width="381">200nm~900nm</td>
</tr>
<tr>
<td width="194">Excitation Slit</td>
<td width="381">1nm/2nm/5nm/10nm/20nm</td>
</tr>
<tr>
<td width="194">Emission Slit</td>
<td width="381">1nm/2nm/5nm/10nm/20nm</td>
</tr>
<tr>
<td width="194">Wavelength Accuracy</td>
<td width="381">±0.4nm</td>
</tr>
<tr>
<td width="194">Wavelength Repeatability</td>
<td width="381">≤0.2nm</td>
</tr>
<tr>
<td width="194">Signal-to-Noise Ratio</td>
<td width="381">S/N≥350(P-P)  S/N≥1000(RMS)</td>
</tr>
<tr>
<td width="194">Limit</td>
<td width="381">≤5×10<sup>-11</sup> g/ml（Quinine Sulfate Solution）</td>
</tr>
<tr>
<td width="194">Linearity</td>
<td width="381">γ≥0.995</td>
</tr>
<tr>
<td width="194">Peak Repeatability</td>
<td width="381">≤1.5%</td>
</tr>
<tr>
<td width="194">Wavelength Scan Speed</td>
<td width="381">Multi-speed Level, Maximum at 60000nm/min</td>
</tr>
<tr>
<td width="194">Minimum sample size</td>
<td width="381">0.5mL (Using a standard 10mm square sample cell)</td>
</tr>
<tr>
<td width="194">Octave filter</td>
<td width="381">Build in Octave filter</td>
</tr>
<tr>
<td width="194">Photometric Quantity Range</td>
<td width="381">-9999 ~ 9999</td>
</tr>
<tr>
<td width="194">Response Time</td>
<td width="381">0.02/0.1/0.5/1/2/4/8 s，Auto adjust</td>
</tr>
<tr>
<td width="194">Data Transportation</td>
<td width="381">USB 2.0</td>
</tr>
<tr>
<td width="194">Power</td>
<td width="381">200W</td>
</tr>
<tr>
<td width="194">Power Source</td>
<td width="381">AC 220V/50Hz； 110V/60Hz</td>
</tr>
<tr>
<td width="194">Instrument Dimension</td>
<td width="381">610×460×365（mm）</td>
</tr>
<tr>
<td width="194">Weight</td>
<td width="381">Net Weight：21kg, Gross Weight：26kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-a-fluorescence/">Spectrophotomètre à fluorescence</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Spectrophotomètre visible, portable</title>
		<link>https://muniatech.com/produit/spectrophotometre-visible-portable/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 08 Jan 2023 11:25:26 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4134</guid>

					<description><![CDATA[<h2>Description</h2>
<p>The portable spectrophotometer is compact in appearance and powerful in function. It adopts a 482X272 true color touch screen, and the humanized design is easier to operate. It meets the needs of different customers and is widely used in teaching and daily analysis.</p>
<p><strong><b>Features</b></strong></p>
<ol>
<li><b></b><strong><b>Luminosity measuremen</b></strong><strong><b>t </b></strong><strong><b>(multi-wavelength test)</b></strong></li>
</ol>
<p>Test the absorbance, transmittance and energy of the sample at a certain wavelength, and measure the results at multiple arbitrary wavelengths at the same time.</p>
<ol start="2">
<li><b></b><strong><b>Quantitative test</b></strong></li>
</ol>
<p>Establish a standard curve for concentration test.</p>
<ol start="3">
<li><b></b><strong><b>Time scan</b></strong><strong><b>ning </b></strong></li>
</ol>
<p>Measure the change pattern, calculate the reaction rate(SP-HVP-A8L).</p>
<ol start="4">
<li><b></b><strong><b>Wavelength scan</b></strong><strong><b>ning</b></strong><strong><b>(spectral scan</b></strong><strong><b>ning</b></strong><strong><b>)</b></strong></li>
</ol>
<p>Can set the scanning range, interval and speed(SP-HVP-A8S).</p>
<ol start="5">
<li><b></b><strong><b>Prefabrication program</b></strong></li>
</ol>
<p>Stored programs are pre-programmed methods for reagents, tube tests, and pipette tests.</p>
<ol start="6">
<li><b></b><strong><b>User presets</b></strong><strong><b>program</b></strong></li>
</ol>
<p>Users make “measurement analysis” possible: Users can program their own developed methods. Stored methods can be saved as user programs. The test can then be modified to suit the user’s requirements.</p>
<ol start="7">
<li><b></b><strong><b>Common </b></strong><strong><b>p</b></strong><strong><b>rocedures</b></strong></li>
</ol>
<p>List of common methods/tests selected by the user.</p>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-visible-portable/">Spectrophotomètre visible, portable</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="172"><strong>Model</strong></td>
<td width="103"><strong>SP-HVP-A8</strong></td>
<td width="114"><strong>SP-HVP-A8L</strong></td>
<td width="114"><strong>SP-HVP-A8S</strong></td>
<td width="158"><strong>SP-HVP-A8P</strong></td>
</tr>
<tr>
<td width="172">Spectral Bandwidth</td>
<td width="103">6nm</td>
<td width="114">5nm</td>
<td width="114">4nm</td>
<td width="158">4nm</td>
</tr>
<tr>
<td width="172">Wavelength Range</td>
<td colspan="4" width="490">190-1100nm</td>
</tr>
<tr>
<td width="172">Optical System</td>
<td colspan="4" width="490">Split beam, optical path, holographic diffraction grating</td>
</tr>
<tr>
<td width="172">Wavelength Accuracy</td>
<td width="103">±3nm</td>
<td width="114">±2nm</td>
<td width="114">±1.5nm</td>
<td width="158">±1.5nm</td>
</tr>
<tr>
<td width="172">Wavelength Repeatability</td>
<td colspan="4" width="490">≤0.5nm</td>
</tr>
<tr>
<td width="172">Wavelength Setting</td>
<td colspan="4" width="490">Automatically set wavelength, wavelength resolution: 0.1nm</td>
</tr>
<tr>
<td width="172">Luminosity Range</td>
<td colspan="4" width="490">-0.602-4.0A  0-400%T</td>
</tr>
<tr>
<td width="172">Luminosity Accuracy</td>
<td colspan="4" width="490">±0.002A (0-0.5A), ±0.004A (0.5-1A), ±0.3%T (0-100%T)</td>
</tr>
<tr>
<td width="172">Luminosity Repeatability</td>
<td colspan="4" width="490">≤0.001A (0-0.5A), ≤0.002A (0.5-1A), ≤0.3%T (0-100%T)</td>
</tr>
<tr>
<td width="172">Stray Light</td>
<td colspan="4" width="490">≤0.1%T (360nm)</td>
</tr>
<tr>
<td width="172">Baseline Drift (Stability)</td>
<td colspan="4" width="490">≤0.001A/h (500nm,0A)</td>
</tr>
<tr>
<td width="172">Detector</td>
<td colspan="4" width="490">Double imported silicon photodiode</td>
</tr>
<tr>
<td width="172">Light Source</td>
<td colspan="4" width="490">Xenon pulse lamp(optical debugging free)</td>
</tr>
<tr>
<td width="172">Display</td>
<td colspan="4" width="490">480*272 , 5-inch color touch screen</td>
</tr>
<tr>
<td width="172">Printout</td>
<td colspan="4" width="490">Micro printer; PC printer (online use)</td>
</tr>
<tr>
<td width="172">Electricity</td>
<td colspan="4" width="490">DC12V 3A</td>
</tr>
<tr>
<td width="172">External Dimension(W*D*H)</td>
<td colspan="4" width="490">270 x 200 x 120mm</td>
</tr>
<tr>
<td width="172">Net Weight</td>
<td colspan="4" width="490">2.6kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-visible-portable/">Spectrophotomètre visible, portable</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Spectrophotomètre UV-Visible, double faisceau</title>
		<link>https://muniatech.com/produit/spectrophotometre-uv-visible-double-faisceau/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 08 Jan 2023 11:03:40 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4132</guid>

					<description><![CDATA[<h2>Description</h2>
<div class="fusion-text fusion-text-1">
<ul>
<li>Automatic zero and full-scale adjustment</li>
<li>Automatic wavelength settings</li>
<li>UV WIN8 Spectrum Data Processing Software optional</li>
</ul>
<p><strong>Main Features of Double Beam UV-Vis Spectrophotometer SP-IUV7</strong><br />
1. Double beam optical system, and blazed holographic<br />
2. G They have outstanding test precision and very competitive prices.<br />
3. 8-inch color touchscreen, cutting-edge user interface, powerful functions, and easy operation.<br />
4. With powerful functions, the equipment shows great performance in qualitative and quantitative testing, such as:</p>
<ul>
<li>Full-spectrum scanning</li>
<li>Linear regression</li>
<li>Detailed spectrum scanning</li>
<li>Concentration direct reading</li>
<li>Time-based kinetics determination</li>
<li>Peak/Valley detecting</li>
<li>GOTO λ</li>
<li>Multi-wavelength measurement</li>
</ul>
<p>5. The equipment is designed with a sophisticated power protection system. With a high capacity of internal memory, it can store testing results, scanned images, regression equations, and correction data. Therefore, it follows a fast initialization when power is on.<br />
6. The instrument can be connected with a dedicated printer, which can print testing results, or draw curves from spectral scanning, fixed wavelength time-based scanning, and linear regression.<br />
7. With a USB COM port the device can be connected to a PC, which can not only enhance the performance in data testing and spectrum scanning but also expand the memory to save more testing results.</p>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-uv-visible-double-faisceau/">Spectrophotomètre UV-Visible, double faisceau</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td>Photometry</td>
<td width="447">Double Beam</td>
</tr>
<tr>
<td>Monochromator Type</td>
<td width="447">Czerny-Turner</td>
</tr>
<tr>
<td>Focal Length</td>
<td width="447">160mm</td>
</tr>
<tr>
<td>Grating</td>
<td width="447">1200 lines/mm</td>
</tr>
<tr>
<td>Detector</td>
<td width="447">Silicon Photocell</td>
</tr>
<tr>
<td>Spectrum Bandwidth</td>
<td width="447">1.8nm</td>
</tr>
<tr>
<td>Wavelength Setting</td>
<td width="447">8-inch color touch-screen</td>
</tr>
<tr>
<td>Wavelength Range</td>
<td width="447">190-1100nm</td>
</tr>
<tr>
<td>Wavelength Accuracy</td>
<td width="447">±0.5nm</td>
</tr>
<tr>
<td>Wavelength Repeatability</td>
<td width="447">≤0.2nm</td>
</tr>
<tr>
<td>Scanning Speed</td>
<td width="447">Fast-Medium-Slow</td>
</tr>
<tr>
<td>Stray Light</td>
<td width="447">≤0.03%T (at 220nm NaI, 360nm NaNo<sub>2</sub>)</td>
</tr>
<tr>
<td>Photometric Range</td>
<td width="447">0.0-200.0%T<br />
-0.301-4.000A<br />
0.000-9999C</td>
</tr>
<tr>
<td>Photometric Accuracy</td>
<td width="447">±0.3%T<br />
±0.002Abs (0-0.5A)<br />
±0.004 Abs (0.5-1A)</td>
</tr>
<tr>
<td>Photometric Repeatability</td>
<td width="447">≤0.15%T<br />
0.001 Abs (0-0.5A)<br />
0.002 Abs (0.5-1A)</td>
</tr>
<tr>
<td>Baseline</td>
<td width="447">≤±0.002A (200-1090nm)</td>
</tr>
<tr>
<td>Noise</td>
<td width="447">100%（T）noise≤0.15%(T), 0%（T）noise≤0.1%(T)</td>
</tr>
<tr>
<td>Drifting</td>
<td width="447">≤0.0009 Abs/30min (250nm and 500nm after 2h warm up)</td>
</tr>
<tr>
<td>Power</td>
<td width="447">AC220V±22V 50Hz±1Hz, 200W</td>
</tr>
<tr>
<td>Packaging Size</td>
<td width="447">710mm×590mm×505mm, 36kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-uv-visible-double-faisceau/">Spectrophotomètre UV-Visible, double faisceau</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Spectrophotomètre UV-visible, simple faisceau</title>
		<link>https://muniatech.com/produit/spectrophotometre-uv-visible-simple-faisceau/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 08 Jan 2023 10:48:06 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4127</guid>

					<description><![CDATA[<h2>Description</h2>
<p><strong>Common Features</strong></p>
<ol>
<li>High quality silicon photometric diode detector and 1200 lines/mm diffraction grating ensure thehigh quality accuracy and precision.</li>
<li>Backlit LCD display for an easy readout.</li>
<li>Automatic 0A and 100%T.</li>
<li>Easy switching of transmittance, absorbance and concentration modes, just by pressing one key.</li>
<li>Direct concentration read-out and concentration factor setting function.</li>
<li>Large sample compartment, for 5 – 100mm path length cuvettes with optional holders.</li>
<li>Easy to change the halogen lamp or deuterium lamp by the user himself.</li>
</ol>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-uv-visible-simple-faisceau/">Spectrophotomètre UV-visible, simple faisceau</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="140"><strong>Model</strong></td>
<td width="91"><strong>SP-IV722G</strong></td>
<td width="146"><strong>SP-IV721G-100</strong></td>
<td width="122"><strong>SP-IV721G</strong></td>
</tr>
<tr>
<td width="140">Photometry</td>
<td colspan="3" width="359">Single Beam</td>
</tr>
<tr>
<td width="140">Monochromator Type</td>
<td colspan="3" width="359">Czerny-Turner</td>
</tr>
<tr>
<td width="140">Detector</td>
<td colspan="3" width="359">Silicon Photocell</td>
</tr>
<tr>
<td width="140">Wavelength Setting</td>
<td colspan="3" width="359">Manual Turn Knob</td>
</tr>
<tr>
<td width="140">Wavelength Range</td>
<td width="91">325-1000nm</td>
<td colspan="2" width="268">340-1000nm</td>
</tr>
<tr>
<td width="140">Wavelength Accuracy</td>
<td colspan="3" width="359">±2nm</td>
</tr>
<tr>
<td width="140">Wavelength Repeatability</td>
<td colspan="3" width="359">≤1nm</td>
</tr>
<tr>
<td width="140">Spectrum Bandwidth</td>
<td colspan="3" width="359">5nm</td>
</tr>
<tr>
<td rowspan="2" width="140">Stray Light</td>
<td colspan="3" width="359">≤0.5%T</td>
</tr>
<tr>
<td colspan="3" width="359">(at 360nm NaNo<sub>2</sub>)</td>
</tr>
<tr>
<td rowspan="3" width="140">Photometric Range</td>
<td colspan="3" width="359">0-100.0%T</td>
</tr>
<tr>
<td colspan="3" width="359">0-1.999A</td>
</tr>
<tr>
<td colspan="3" width="359">0-1999C</td>
</tr>
<tr>
<td width="140">Photometric Accuracy</td>
<td colspan="3" width="359">±0.5%T</td>
</tr>
<tr>
<td width="140">Photometric Repeatability</td>
<td colspan="3" width="359">≤0.2%T</td>
</tr>
<tr>
<td width="140">Noise</td>
<td colspan="3" width="359">100%（T）noise≤0.3%(T) ， 0%（T）noise≤0.2%(T)</td>
</tr>
<tr>
<td width="140">Drifting</td>
<td colspan="3" width="359">±0.5 %T/3min</td>
</tr>
<tr>
<td width="140">Cuvette Holder Size</td>
<td width="91">50mm</td>
<td width="146">100mm</td>
<td width="122">50mm</td>
</tr>
<tr>
<td width="140">Power</td>
<td colspan="3" width="359">AC220V±22V 50Hz±1Hz, 50W</td>
</tr>
<tr>
<td width="140">Packaging Size</td>
<td colspan="3" width="359">560*500*300mm 0.08M³</td>
</tr>
<tr>
<td width="140">N.W./ G.W.</td>
<td colspan="3" width="359">13/ 14kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-uv-visible-simple-faisceau/">Spectrophotomètre UV-visible, simple faisceau</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Spectrophotomètre UV-Visible</title>
		<link>https://muniatech.com/produit/spectrophotometre-uv-visible/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 08 Jan 2023 10:29:51 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4124</guid>

					<description><![CDATA[<h2>Description</h2>
<p>1. Sample compartment for 5-50mm cuvettes</p>
<p>2. Precise automatic T/A changeover</p>
<p>3. Automatic zero and full-scale adjustment</p>
<p>4. 7-inch multi color touchscreen (SP-IUV752N Plus and SP-IV722N)</p>
<p>5. Equipped with USB port</p>
<p>6. Direct concentration read-out and concentration factor setting function</p>
<p>7. Automatic light gate technology to protect photoelectric sensors</p>
<p>8. Standard software</p>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-uv-visible/">Spectrophotomètre UV-Visible</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="206"><strong>Model</strong></td>
<td width="158"><strong>SP-IV722N</strong></td>
<td width="187"><strong>SP-IV721N</strong></td>
</tr>
<tr>
<td width="206">Photometry</td>
<td colspan="2" width="346">Single Beam</td>
</tr>
<tr>
<td width="206">Monochromator Type</td>
<td colspan="2" width="346">Czerny-Turner</td>
</tr>
<tr>
<td width="206">Focal Length</td>
<td colspan="2" width="346">160mm</td>
</tr>
<tr>
<td width="206">Grating</td>
<td colspan="2" width="346">1200 lines/mm</td>
</tr>
<tr>
<td width="206">Detector</td>
<td colspan="2" width="346">Silicon Photocell</td>
</tr>
<tr>
<td width="206">Wavelength Setting</td>
<td colspan="2" width="346">Manual Turn Knob</td>
</tr>
<tr>
<td width="206">Wavelength Range</td>
<td width="158">325-1000nm</td>
<td width="187">340-1000nm</td>
</tr>
<tr>
<td width="206">Wavelength Accuracy</td>
<td colspan="2" width="346">±2nm</td>
</tr>
<tr>
<td width="206">Wavelength Repeatability</td>
<td colspan="2" width="346">≤1nm</td>
</tr>
<tr>
<td width="206">Spectrum Bandwidth</td>
<td width="158">2nm</td>
<td width="187">5nm</td>
</tr>
<tr>
<td width="206">Stray Light</td>
<td colspan="2" width="346">≤0.1 (at 360nm NaNo2)</td>
</tr>
<tr>
<td width="206">Photometric Range</td>
<td colspan="2" width="346">0-100.0%T</td>
</tr>
<tr>
<td width="206"></td>
<td colspan="2" width="346">0-1.999A</td>
</tr>
<tr>
<td width="206"></td>
<td colspan="2" width="346">0-1999C</td>
</tr>
<tr>
<td width="206">Photometric Accuracy</td>
<td colspan="2" width="346">±0.5%T</td>
</tr>
<tr>
<td width="206">Photometric Repeatability</td>
<td colspan="2" width="346">≤0.2%T</td>
</tr>
<tr>
<td width="206">Noise</td>
<td colspan="2" width="346">100%（T）noise≤0.3%(T), 0%（T）noise≤0.2%(T)</td>
</tr>
<tr>
<td width="206">Cuvette Holder Size</td>
<td colspan="2" width="346">10mm</td>
</tr>
<tr>
<td width="206">Packaging Size</td>
<td colspan="2" width="346">580mm×460mm×345mm 0.1M 3</td>
</tr>
<tr>
<td width="206">Power</td>
<td colspan="2" width="346">AC220V±22V 50Hz±1Hz,80W</td>
</tr>
<tr>
<td width="206">G.W.</td>
<td colspan="2" width="346">12.5kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/spectrophotometre-uv-visible/">Spectrophotomètre UV-Visible</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
	</channel>
</rss>
