<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Instruments d&#039;analyses - Muniatech</title>
	<atom:link href="https://muniatech.com/categorie-produit/instruments-danalyses/feed/" rel="self" type="application/rss+xml" />
	<link>https://muniatech.com/categorie-produit/instruments-danalyses/</link>
	<description>Performance delivred</description>
	<lastBuildDate>Sun, 25 Dec 2022 14:26:01 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.5</generator>

<image>
	<url>https://muniatech.com/wp-content/uploads/2022/05/cropped-NewIcon-32x32.png</url>
	<title>Instruments d&#039;analyses - Muniatech</title>
	<link>https://muniatech.com/categorie-produit/instruments-danalyses/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Analyseur HbA1c automatique portable</title>
		<link>https://muniatech.com/produit/analyseur-hba1c-automatique-portable/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 25 Dec 2022 14:26:01 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4025</guid>

					<description><![CDATA[<h2>Description</h2>
<p><strong>Key features</strong></p>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<ul>
<li>Portable Glycated Hemoglobin Analyzer</li>
<li>Fast test time: ≤3.5min</li>
<li>Providing voice guidance; 4.0%~15.0% test range for HbA1c</li>
<li>Reflect the control of glycemic before the past 2~3 months</li>
</ul>
<p><strong>Product overview</strong></p>
<ul>
<li>Clinically, The HbA1c Monitoring System is mainly used for auxiliary diagnosis of diabetes and monitoring of average blood glucose level.</li>
<li>The HbA1c Monitoring System consists of a PCH-100 HbA1c analyzer and HbA1c Reagent Kit.<br />
The HbA1c Reagent Kit is designed to be used with the PCH-100 HbA1c Analyzer to quantitatively determine hemoglobin A1c (HbA1c) in capillary (fingerprick) or venous whole blood</li>
<li>PCH-100 employs solid-phase reflection method to quantitatively measure the percentage of hemoglobin A1c (HbA1c) among total hemoglobin.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-hba1c-automatique-portable/">Analyseur HbA1c automatique portable</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="text-center" width="454" data-sort="sortDisabled">
<tbody>
<tr>
<td>Test method</td>
<td>Relative deviation≤±10%</td>
</tr>
<tr>
<td>Precision</td>
<td>Coefficient of variation (CV)≤8%</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null" width="205">Measurement range</td>
<td rowspan="1" align="null" valign="null" width="205">4.0%~15.0%</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null">Blood sample</td>
<td colspan="1" rowspan="1" valign="null">fresh capillary whole blood, venous whole blood</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null">Test time</td>
<td colspan="1" rowspan="1" valign="null">≤3.5mins</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null">Sample size</td>
<td colspan="1" rowspan="1" valign="null">5µl</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null">HCT</td>
<td colspan="1" rowspan="1" valign="null">30-60%</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null">Test Temperature</td>
<td colspan="1" rowspan="1" valign="null">15℃</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null">Reagent storage condition</td>
<td colspan="1" rowspan="1" valign="null">2-8℃；Do not freeze</td>
</tr>
<tr>
<td colspan="1" rowspan="2" valign="null">Expiry date</td>
<td colspan="1" rowspan="1" valign="null">Un-opened: 12 months</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null">Opened: 4 hours</td>
</tr>
<tr>
<td colspan="1" rowspan="1" valign="null">Printer</td>
<td colspan="1" rowspan="1" valign="null">Built-in thermal printer</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-hba1c-automatique-portable/">Analyseur HbA1c automatique portable</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Analyseur HbA1c semi-automatique</title>
		<link>https://muniatech.com/produit/analyseur-hba1c-semi-automatique/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 25 Dec 2022 13:37:19 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4023</guid>

					<description><![CDATA[<h2>Description</h2>
<p><strong>Key features</strong></p>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<ul>
<li>Semi-automated analyzer</li>
<li>Result in just four (04) minutes</li>
<li>µl sample size required</li>
<li>Intuitive, step by step on screen instructions minimize training time</li>
<li>Multi-lingual menu</li>
<li>Just 4 µl blood required from finger prick or venous sample</li>
</ul>
<p><strong>Efficient data handling</strong></p>
<ul>
<li>Barcode reader included. Only one scan per lot of cartridges required</li>
<li>Stores over 7,000 results for efficient patient data management</li>
<li>User selectable dual reporting. User can select % DCCT, IFCC mmol/mol, eAG mg/dl or eAG mmol/l</li>
<li>USB port</li>
</ul>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-hba1c-semi-automatique/">Analyseur HbA1c semi-automatique</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="301">Test method</td>
<td width="301">boronated affinity method which is recognized as interference free</td>
</tr>
<tr>
<td width="301">Applications</td>
<td width="301">for clinical diagnostic, for diabetes</td>
</tr>
<tr>
<td width="301">Configuration</td>
<td width="301">benchtop</td>
</tr>
<tr>
<td width="301">Blood samples</td>
<td width="301">fresh capillary whole blood, venous whole blood</td>
</tr>
<tr>
<td width="301">Test time</td>
<td width="301">≤4mins</td>
</tr>
<tr>
<td width="301">Sample size</td>
<td width="301">0,004 ml (0,000135 US fl oz)</td>
</tr>
<tr>
<td width="301">Test storage capacity</td>
<td width="301">7 000 unit</td>
</tr>
<tr>
<td width="301">Measuring range</td>
<td width="301">4–15 % A1c DCCT</td>
</tr>
<tr>
<td width="301">Imprecision</td>
<td width="301">CV &lt;3 % at 7 % A1c DCCT</td>
</tr>
<tr>
<td width="301">Dimension</td>
<td width="301">95(L) x 205(W) x 135(H)mm</td>
</tr>
<tr>
<td width="301">Weight</td>
<td width="301">0.7 kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-hba1c-semi-automatique/">Analyseur HbA1c semi-automatique</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Analyseur HbA1c automatique</title>
		<link>https://muniatech.com/produit/analyseur-hba1c-automatique/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 25 Dec 2022 13:22:30 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=4020</guid>

					<description><![CDATA[<h2>Description</h2>
<p><strong>Key features</strong></p>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<ul>
<li>Fully automated analyzer</li>
<li>Result in just four (04) minutes</li>
<li>µl sample size required</li>
<li>Intuitive, step by step on screen instructions minimize training time</li>
<li>Multi-lingual menu</li>
<li>Just 4 µl blood required from finger prick or venous sample</li>
</ul>
<p><strong>Efficient data handling</strong></p>
<ul>
<li>Barcode reader included. Only one scan per lot of cartridges required</li>
<li>Stores over 7,000 results for efficient patient data management</li>
<li>User selectable dual reporting. User can select % DCCT, IFCC mmol/mol, eAG mg/dl or eAG mmol/l</li>
<li>USB port</li>
</ul>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-hba1c-automatique/">Analyseur HbA1c automatique</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="301">Test method</td>
<td width="301">boronated affinity method which is recognized as interference free</td>
</tr>
<tr>
<td width="301">Applications</td>
<td width="301">for clinical diagnostic, for diabetes</td>
</tr>
<tr>
<td width="301">Configuration</td>
<td width="301">benchtop</td>
</tr>
<tr>
<td width="301">Blood samples</td>
<td width="301">fresh capillary whole blood, venous whole blood</td>
</tr>
<tr>
<td width="301">Test time</td>
<td width="301">≤4mins</td>
</tr>
<tr>
<td width="301">Sample size</td>
<td width="301">0,004 ml (0,000135 US fl oz)</td>
</tr>
<tr>
<td width="301">Test storage capacity</td>
<td width="301">7 000 unit</td>
</tr>
<tr>
<td width="301">Measuring range</td>
<td width="301">4–15 % A1c DCCT</td>
</tr>
<tr>
<td width="301">Imprecision</td>
<td width="301">CV &lt;3 % at 7 % A1c DCCT</td>
</tr>
<tr>
<td width="301">Dimension</td>
<td width="301">205(L) x 205(W) x 135(H)mm</td>
</tr>
<tr>
<td width="301">Weight</td>
<td width="301">1.3 kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-hba1c-automatique/">Analyseur HbA1c automatique</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Coagulomètre automatique portable</title>
		<link>https://muniatech.com/produit/coagulometre-automatique-portable/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 16 Oct 2022 12:58:57 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3837</guid>

					<description><![CDATA[<h2>Description</h2>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<p>1. Double magnetic route<br />
2. Auto-linked pipette<br />
3. Testing channel: BCA-SA-4-16<br />
4. 7’’ color Touch Screen<br />
5. Built-in thermal printer<br />
<strong>Performance</strong><br />
1. Double magnetic route, stable performance without interference<br />
2. The CPU adopts ARM technology to measure the motion of the magnetic ball to work out the coagulation time<br />
3. It can perform multi-parameter simultaneously with better accuracy, precision, and repetition<br />
4. 100 assay parameters and 1000 test results can be saved<br />
5. Clock CMOS chip inserted<br />
6. Reagent-open system<br />
7. Built-in thermal printer<br />
8. Interface: RS232, USB, pipette-linked port<br />
9. Power supply: AC220V±15%, 50Hz, 80VA</p>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/coagulometre-automatique-portable/">Coagulomètre automatique portable</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="301">Test method</td>
<td width="301">double magnetic route</td>
</tr>
<tr>
<td width="301">Sample consumption</td>
<td width="301">≤200uL</td>
</tr>
<tr>
<td width="301">Reagent consumption</td>
<td width="301">50uL~200uL</td>
</tr>
<tr>
<td width="301">Temperature</td>
<td width="301">37℃±0.5℃</td>
</tr>
<tr>
<td width="301">Adding sample</td>
<td width="301">by a timing linkage</td>
</tr>
<tr>
<td width="301">Precision</td>
<td width="301">CV ≤3%</td>
</tr>
<tr>
<td width="301">Test speed</td>
<td width="301">≤300s(depend on setting)</td>
</tr>
<tr>
<td width="301">Sample warming up position</td>
<td width="301">16</td>
</tr>
<tr>
<td width="301">Reagent warming up position</td>
<td width="301">6</td>
</tr>
<tr>
<td width="301">Dimension</td>
<td width="301">370(L)x290(W)x120(H)mm</td>
</tr>
<tr>
<td width="301">Weight</td>
<td width="301">4Kg(net), 6Kg(gross)</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/coagulometre-automatique-portable/">Coagulomètre automatique portable</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Coagulomètre automatique &#8211; 6 tubes</title>
		<link>https://muniatech.com/produit/coagulometre-automatique-6-tubes/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 16 Oct 2022 12:50:28 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3835</guid>

					<description><![CDATA[<h2>Description</h2>
<p>The full-automatic coagulation tester adopts the solid test method and immune turbidimetry test, which is mainly used in the emergency detection of medium and high-end customers, and better meets the full-automatic detection needs of small customers.</p>
<p><strong>Advantages</strong></p>
<ul>
<li>The full-automatic sampling and testing system reduces 20 operating procedures for manual detection of semi-automatic instruments, greatly improving work efficiency.</li>
<li>It not only has the four detection functions of coagulation routine, but also has the detection functions of D-dimer, FDP and other coagulation related special items, so as to provide more complete diagnostic data for clinical practice. The instrument can be connected to Lis system for easy management.</li>
<li>The automatic sample adding, and testing system ensures the consistency and accuracy of test results of different operators and eliminates errors and medical risks caused by manual operation.</li>
<li>With refrigeration function, interchangeable inclined reagent position and sample adding system with constant temperature heating and liquid level sensing, the reagent can be used longer to avoid waste and ensure the accuracy of test results.</li>
<li>The sampling probe has the functions of liquid level induction and constant temperature heating.</li>
<li>Dynamic test solidification curve can be displayed.</li>
<li>With batch test and emergency priority insertion test function.</li>
<li>With abnormal test result alarm and automatic retest function.</li>
<li>With cleaning liquid shortage alarm, waste liquid overflow alarm function.</li>
<li>Optical coagulation method background scanning, remove jaundice, high-fat background interference function.</li>
</ul>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/coagulometre-automatique-6-tubes/">Coagulomètre automatique &#8211; 6 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="284">Test Speed（Ts/h)</td>
<td width="284">100</td>
</tr>
<tr>
<td width="284">Probe</td>
<td width="284">1</td>
</tr>
<tr>
<td width="284">Test Method</td>
<td width="284">Optical</td>
</tr>
<tr>
<td width="284">Test Items</td>
<td width="284">APTT, PT, FIB,TT</td>
</tr>
<tr>
<td width="284">Test Channels</td>
<td width="284">4</td>
</tr>
<tr>
<td width="284">Sample Position</td>
<td width="284">5</td>
</tr>
<tr>
<td width="284">Reagent Position</td>
<td width="284">6</td>
</tr>
<tr>
<td width="284">Refrigeration Function</td>
<td width="284">yes</td>
</tr>
<tr>
<td width="284">Washing Position</td>
<td width="284">1</td>
</tr>
<tr>
<td width="284">Optical Cuvettes Loading</td>
<td width="284">4</td>
</tr>
<tr>
<td width="284">LED Lighting LED</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Insufficient Alarm for Cuvettes, Reagents,Detergent</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Overflow Alarm for Waste Liquid</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">LIS System</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Weight</td>
<td width="284">30Kg</td>
</tr>
<tr>
<td width="284">Dimension</td>
<td width="284">53*47*42cm</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/coagulometre-automatique-6-tubes/">Coagulomètre automatique &#8211; 6 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Coagulomètre automatique &#8211; 20 tubes</title>
		<link>https://muniatech.com/produit/coagulometre-automatique/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 16 Oct 2022 12:38:16 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3831</guid>

					<description><![CDATA[<h2>Description</h2>
<p>It adopts coagulation method, immunoturbidimetric method and chromogenic substrate method, and can test all coagulation related test items such as conventional four items, D-D, FDP, AT, etc</p>
<p><strong>Advantages</strong></p>
<ul>
<li>The combination of automatic sample adding system, pre temperature system, ten channel multi methodology testing system, cup feeding system, manipulator cup grasping system, cleaning system and bar code identification system greatly improves the work efficiency.</li>
<li>It has the detection function of four conventional coagulation items, factors, D-dimer, FDP and other coagulation related special items, so as to provide complete clinical diagnostic data. The instrument can be connected to Lis system to facilitate data management.</li>
<li>The magnetic bead method completely avoids the interference of jaundice, hemolysis and abnormal turbidity of chyle samples, ensures the consistency and accuracy of test results, and eliminates test errors and medical risks.</li>
<li>The inclined reagent position with refrigeration function and the sample adding system with constant temperature heating and liquid level sensing make the reagent use longer to avoid waste and ensure the accuracy of test results.</li>
<li>Test position: The four-channel multi-method test system can test all coagulation items and significantly improve the test speed.</li>
<li>Sample position: Interchangeable sample position to meet the needs of large sample volume. The operation process is convenient and simple.</li>
<li>Injection needle: The micro injection pump and the injection needle are highly integrated. The injection volume and test results are extremely accurate and easy to maintain.</li>
<li>Reagent kit: The instrument is equipped with four coagulation routines, D-dimer, FOP and other coagulation detection reagents, quality control materials, and calibrators are independently developed and produced, with a complete traceability system.</li>
<li>Alarm function: abnormal alarm of test results and automatic repeated test function; When the reagent is insufficient, the sampling probe automatically transposes or reports energy; Insufficient test cup and reagent, insufficient detergent, waste liquid overflow and cover opening alarm function</li>
</ul>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/coagulometre-automatique/">Coagulomètre automatique &#8211; 20 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td width="284">Test Speed (Ts/h)</td>
<td width="284">200</td>
</tr>
<tr>
<td width="284">Probe</td>
<td width="284">1</td>
</tr>
<tr>
<td width="284">Test Method</td>
<td width="284">Coagulation (magnetic beads), Immunoturbidimetry, chromogenic substrate</td>
</tr>
<tr>
<td width="284">Test Items</td>
<td width="284">PT, APTT, FIB, TT, D-dimer, FDP, AT-III, allFactors, FM, APC-R, PC, PS, vWF, HEP, LMWH, AT, PLG, PAI,<br />
TAFI, Free-Ps, AP, HNF/UFH</td>
</tr>
<tr>
<td width="284">Test Channels</td>
<td width="284">4</td>
</tr>
<tr>
<td width="284">Sample Position</td>
<td width="284">35</td>
</tr>
<tr>
<td width="284">Pre-heating Channels</td>
<td width="284">20</td>
</tr>
<tr>
<td width="284">Reagents Position</td>
<td width="284">21（20+1）</td>
</tr>
<tr>
<td width="284">Sampling Arm</td>
<td width="284">1</td>
</tr>
<tr>
<td width="284">Washing Position</td>
<td width="284">1</td>
</tr>
<tr>
<td width="284">Cuvettes Loading System</td>
<td width="284">Drawer style</td>
</tr>
<tr>
<td width="284">Reagent Loading System</td>
<td width="284">Drawer style</td>
</tr>
<tr>
<td width="284">Sample Loading System</td>
<td width="284">Drawer style</td>
</tr>
<tr>
<td width="284">Magnetic Cuvettes Loading</td>
<td width="284">1000</td>
</tr>
<tr>
<td width="284">Auto Positioning</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Integrated Sampling Pump System</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Inner Card Reading Function</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Bar Code Recognition Function</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">LED Lighting</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Four Direction Cooling</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Insufficient Alarm for Cuvettes, Reagents,Detergent</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">LIS System</td>
<td width="284">Yes</td>
</tr>
<tr>
<td width="284">Weight</td>
<td width="284">110Kg</td>
</tr>
<tr>
<td width="284">Dimension</td>
<td width="284">60 x 62 x 65cm</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/coagulometre-automatique/">Coagulomètre automatique &#8211; 20 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Analyseur automatisé ESR &#8211; 10 tubes</title>
		<link>https://muniatech.com/produit/analyseur-automatise-esr-10-tubes/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 16 Oct 2022 11:35:21 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3828</guid>

					<description><![CDATA[<h2>Description</h2>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<ol>
<li>Large color display, touch screen</li>
<li>10 channels, up to 20T/H</li>
<li>Twoworking method: 30 mins or 60 mins</li>
<li>ESR curve display and print out</li>
<li>Barcode reader optional</li>
<li>Can connect LIS</li>
</ol>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-automatise-esr-10-tubes/">Analyseur automatisé ESR &#8211; 10 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td>Field of application</td>
<td>Erythrocyte sedimentation rate analysis</td>
</tr>
<tr>
<td>Measuring principle</td>
<td>Infrared sensor</td>
</tr>
<tr>
<td>Analysis result</td>
<td>Westergren ESR value (mm/hr)</td>
</tr>
<tr>
<td>Throughput</td>
<td>Up to 20 samples per hour</td>
</tr>
<tr>
<td>Reading channels</td>
<td>10</td>
</tr>
<tr>
<td>Loading capacity</td>
<td>10 sample at same time</td>
</tr>
<tr>
<td>Loading pattern</td>
<td>Random</td>
</tr>
<tr>
<td>Measuring time</td>
<td>30 minutes or 60 minutes selectable</td>
</tr>
<tr>
<td>Sample interval</td>
<td>3 minutes</td>
</tr>
<tr>
<td>Measurement range</td>
<td>(1-140) mm/h</td>
</tr>
<tr>
<td>Temperature compensation</td>
<td>Refer to 18°C automatically (selectable)</td>
</tr>
<tr>
<td>Reading resolution</td>
<td>±0.1mm</td>
</tr>
<tr>
<td>Result resolution</td>
<td>1mm/1h, 1mm/2h</td>
</tr>
<tr>
<td>Blood level range</td>
<td>50mm~64mm</td>
</tr>
<tr>
<td>Display</td>
<td>Color LCD screen</td>
</tr>
<tr>
<td>Input</td>
<td>Touch screen</td>
</tr>
<tr>
<td>Interface</td>
<td>RS-232 serial port</td>
</tr>
<tr>
<td>Print</td>
<td>Internal thermal recorder</td>
</tr>
<tr>
<td>Storage</td>
<td>4,000 results</td>
</tr>
<tr>
<td>Power supply</td>
<td>AC100-240V, 50-60Hz, 50W</td>
</tr>
<tr>
<td>Operation conditions</td>
<td>Temperature 5C°~40°C Humidity ≤80%</td>
</tr>
<tr>
<td>Dimension</td>
<td>365mm×300mm×180mm(L×W×H)</td>
</tr>
<tr>
<td>Net weight</td>
<td>11Kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-automatise-esr-10-tubes/">Analyseur automatisé ESR &#8211; 10 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Analyseur automatisé ESR &#8211; 40 tubes</title>
		<link>https://muniatech.com/produit/analyseur-automatise-de-vitesse-de-sedimentation-40-tubes/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 16 Oct 2022 11:06:46 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3824</guid>

					<description><![CDATA[<h2>Description</h2>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<p>1. Large 7-inch touch screen<br />
2.Two working methods: 30mins or 60mins<br />
3.ESR curve display and print out<br />
4.Barcode reader optional, Support LIS connection</p>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-automatise-de-vitesse-de-sedimentation-40-tubes/">Analyseur automatisé ESR &#8211; 40 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td colspan="2"><strong>Principle</strong></td>
</tr>
<tr>
<td>Field of application:</td>
<td>Erythrocyte</td>
</tr>
<tr>
<td>sedimentation rate analysis Measuring principle:</td>
<td>Infrared sensor</td>
</tr>
<tr>
<td>Analysis result:</td>
<td>Westergren ESR value(mm/hr)</td>
</tr>
<tr>
<td colspan="2"><strong>Test speed/Capacity</strong></td>
</tr>
<tr>
<td>Throughput:</td>
<td>Up to 80 samples per hour</td>
</tr>
<tr>
<td>Reading channels:</td>
<td>40</td>
</tr>
<tr>
<td>Loading capacity:</td>
<td>40 samples at same time</td>
</tr>
<tr>
<td>Loading pattern:</td>
<td>Random</td>
</tr>
<tr>
<td>Storage:</td>
<td>4,000 results</td>
</tr>
<tr>
<td colspan="2"><strong>Test range</strong></td>
</tr>
<tr>
<td>Measuring time:</td>
<td>30 minutes or 60 minutes selectable</td>
</tr>
<tr>
<td>Sample interval:</td>
<td>3 minutes</td>
</tr>
<tr>
<td>Measurement range:</td>
<td>(1-140) mm/h</td>
</tr>
<tr>
<td>Temperature compensation: Refer to 18C automatically(selectable) Reading resolution:</td>
<td>±0.1mm</td>
</tr>
<tr>
<td>Result resolution:</td>
<td>1mm/1h,1mm/2h</td>
</tr>
<tr>
<td>Blood level range:</td>
<td>50mm~64mm</td>
</tr>
<tr>
<td colspan="2"><strong>Output/interface</strong></td>
</tr>
<tr>
<td>Interface:</td>
<td>RS-232 serial port</td>
</tr>
<tr>
<td>Print:</td>
<td>Internal thermal recorder</td>
</tr>
<tr>
<td colspan="2">Power/Working condition</td>
</tr>
<tr>
<td>Power supply:</td>
<td>AC100-240V,50-60Hz,50W</td>
</tr>
<tr>
<td>Operation conditions:</td>
<td>Temperature 5C～40℃ Humidity ≤80%</td>
</tr>
<tr>
<td colspan="2">Dimension/Weight</td>
</tr>
<tr>
<td>Dimension:</td>
<td>365mm×300mm×180mm (LxWxH)</td>
</tr>
<tr>
<td>Net weight:</td>
<td>8Kg</td>
</tr>
<tr>
<td>Package</td>
<td>690mm*440mm*340mm, 12.2Kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-automatise-de-vitesse-de-sedimentation-40-tubes/">Analyseur automatisé ESR &#8211; 40 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Analyseur automatisé ESR &#8211; 20 tubes</title>
		<link>https://muniatech.com/produit/analyseur-automatique-esr/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 16 Oct 2022 08:32:34 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3820</guid>

					<description><![CDATA[<h2>Description</h2>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<ol>
<li>Large color display, touch screen</li>
<li>20 channels, up to 40T/H</li>
<li>Two working methods: 30 mins or 60 mins</li>
<li>ESR curve display and print out</li>
<li>Bar code reader (optional)</li>
<li>Can connect LIS</li>
</ol>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-automatique-esr/">Analyseur automatisé ESR &#8211; 20 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specifications</h2>
<table class="table-1">
<tbody>
<tr>
<td>Item</td>
<td>ESR analyzer, 20 sample at same time</td>
</tr>
<tr>
<td>Field of application</td>
<td>Erythrocyte sedimentation rate analysis</td>
</tr>
<tr>
<td>Measuring principle</td>
<td>Infrared sensor</td>
</tr>
<tr>
<td>Analysis result</td>
<td>Westergren ESR value (mm/hr)</td>
</tr>
<tr>
<td>Throughput</td>
<td>Up to 40 samples per hour</td>
</tr>
<tr>
<td>Reading channels</td>
<td>20</td>
</tr>
<tr>
<td>Loading capacity</td>
<td>20 sample at same time</td>
</tr>
<tr>
<td>Loading pattern</td>
<td>Random</td>
</tr>
<tr>
<td>Measuring time</td>
<td>30 minutes or 60 minutes selectable</td>
</tr>
<tr>
<td>Sample interval</td>
<td>3 minutes</td>
</tr>
<tr>
<td>Measurement range</td>
<td>(1-140)mm/h</td>
</tr>
<tr>
<td>Temperature compensation</td>
<td>Refer to 18°C automatically (selectable)</td>
</tr>
<tr>
<td>Reading resolution</td>
<td>±0.1mm</td>
</tr>
<tr>
<td>Result resolution</td>
<td>1mm/1h, 1mm/2h</td>
</tr>
<tr>
<td>Blood level range</td>
<td>50mm~64mm</td>
</tr>
<tr>
<td>Display</td>
<td>7-inch Color LCD screen</td>
</tr>
<tr>
<td>Input</td>
<td>Touch screen</td>
</tr>
<tr>
<td>Interface</td>
<td>RS-232 serial port</td>
</tr>
<tr>
<td>Print</td>
<td>Internal thermal recorder</td>
</tr>
<tr>
<td>Storage</td>
<td>4,000 results</td>
</tr>
<tr>
<td>Power supply</td>
<td>AC100-240V, 50-60Hz, 50W</td>
</tr>
<tr>
<td>Operation conditions</td>
<td>Temperature 5C°~40°C Humidity ≤80%</td>
</tr>
<tr>
<td>Dimension</td>
<td>365mm×300mm×180mm(L×W×H)</td>
</tr>
<tr>
<td>Net weight</td>
<td>11Kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-automatique-esr/">Analyseur automatisé ESR &#8211; 20 tubes</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Coagulomètre semi-automatique 2 canaux</title>
		<link>https://muniatech.com/produit/coagulometre-semi-automatique-2-canaux/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Mon, 26 Sep 2022 22:02:54 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3812</guid>

					<description><![CDATA[<h2>Description</h2>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<p>Coagulation analyzer is a routine testing medical device that measures the content of various components in human blood, quantifies the results of biochemical analysis, and provides reliable digital basis for clinical diagnosis of various diseases of patients.</p>
<p><strong><b>Features</b></strong></p>
<ul>
<li>Advanced scattered light principle and percentage analysis ensure accurate results.</li>
<li>Low reagent consumption less than 20μL, open reagent.</li>
<li>Special testing cup location system, adding sample bracket</li>
<li>Optional PT Derived method for testing fibrinogen, decease the dosage of reagent</li>
<li>Advanced optical light matching system ensure precision result.</li>
<li>240*128 large LCD display.</li>
<li>Memory for 10,000 testing result</li>
<li>Internal thermal-sensitive printer</li>
<li>Electronically linked pipette optional.</li>
<li>Perform all routine tests such as PT. APTT. TT Fibrinogen and clotting factors</li>
<li>RS232 interface, PC connecting for management software</li>
</ul>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/coagulometre-semi-automatique-2-canaux/">Coagulomètre semi-automatique 2 canaux</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Specifications</strong></h2>
<table class="table-1">
<tbody>
<tr>
<td width="284">Testing channels</td>
<td width="334">2 channel; 2 different parameters analysis in the same time</td>
</tr>
<tr>
<td width="284">Sample pre-warming position</td>
<td width="334">16 positions</td>
</tr>
<tr>
<td width="284">Reagent pre-warming position</td>
<td width="334">3 positions</td>
</tr>
<tr>
<td width="284">Software timer</td>
<td width="334">2</td>
</tr>
<tr>
<td width="284">Test wavelength</td>
<td width="334">470nm</td>
</tr>
<tr>
<td width="284">Sample consumption</td>
<td width="334">20μL-40μL</td>
</tr>
<tr>
<td width="284">Reagent consumption</td>
<td width="334">20μL-40μL</td>
</tr>
<tr>
<td width="284">Temp control precision</td>
<td width="334">37±0.3℃</td>
</tr>
<tr>
<td width="284">Repeatability</td>
<td width="334">CV &lt; 2%</td>
</tr>
<tr>
<td width="284">Coincidence indicator</td>
<td width="334">≤3%</td>
</tr>
<tr>
<td width="284">Memory</td>
<td width="334">10000 test result</td>
</tr>
<tr>
<td width="284">Notation of Result</td>
<td width="334">S, %, PTR, INR, g/L</td>
</tr>
<tr>
<td width="284">Operation language</td>
<td width="334">English</td>
</tr>
<tr>
<td width="284">Electricity</td>
<td width="334">220VAC±15% 50-60Hz</td>
</tr>
<tr>
<td width="284">Dimensions(L*W*H)</td>
<td width="334">380*320*230mm</td>
</tr>
<tr>
<td width="284">Packing dimensions(L*W*H)</td>
<td width="334">500*460*290mm</td>
</tr>
<tr>
<td width="284">Working environment</td>
<td width="334">Temperature: 15℃-30℃; Humidity≤90%</td>
</tr>
<tr>
<td width="284">Net weight</td>
<td width="334">6.5kg</td>
</tr>
<tr>
<td width="284">Gross weight</td>
<td width="334">8.5kg</td>
</tr>
<tr>
<td width="284">Optional language</td>
<td width="334">English; French; Spanish; Portuguese; Indonesian</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/coagulometre-semi-automatique-2-canaux/">Coagulomètre semi-automatique 2 canaux</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
	</channel>
</rss>
