<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Analyseurs électrolytiques - Muniatech</title>
	<atom:link href="https://muniatech.com/categorie-produit/instruments-danalyses/analyseurs-electrolytiques/feed/" rel="self" type="application/rss+xml" />
	<link>https://muniatech.com/categorie-produit/instruments-danalyses/analyseurs-electrolytiques/</link>
	<description>Performance delivred</description>
	<lastBuildDate>Mon, 26 Sep 2022 21:27:57 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.5</generator>

<image>
	<url>https://muniatech.com/wp-content/uploads/2022/05/cropped-NewIcon-32x32.png</url>
	<title>Analyseurs électrolytiques - Muniatech</title>
	<link>https://muniatech.com/categorie-produit/instruments-danalyses/analyseurs-electrolytiques/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Analyseur d&#8217;électrolyte</title>
		<link>https://muniatech.com/produit/analyseur-delectrolyte-2/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Mon, 26 Sep 2022 21:27:57 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3808</guid>

					<description><![CDATA[<h2>Description</h2>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<p>Electrolyte analyzers are indispensable in clinical testing. In clinical practice, it mainly tests and maintains the balance of osmotic pressure in human blood and body fluids; in surgery, burns, diarrhea, acute myocardial infarction and other patients who need a large amount of balanced fluid replacement, the test and detection of ions are very important. EA Series Electrolyte Analyzers are highly precise and accurate, providing accurate, reliable, fast, and easy-to-use results for any sample. Therefore, ion detection is an essential general equipment for hospitals at all levels.</p>
<p><strong><b>Features</b></strong></p>
<p><strong><b>Easy to operate:</b></strong></p>
<ul>
<li>The instrument only has YES and NO keys, concise menu display, simple and clear operation.</li>
<li>The user can switch the instrument on and off at any time 24 hours as needed to save costs.</li>
</ul>
<p><strong><b>Accurate measurement:</b></strong></p>
<ul>
<li>Adopt advanced ion measuring technology to ensure accurate measurement;</li>
<li>Imported electrode raw materials, long service life.</li>
<li>German CO2 sensor with a service life of up to 10 years;</li>
<li>Adopt automatic potential tracking correction technology to ensure measurement stability;</li>
</ul>
<p><strong><b>A</b></strong><strong><b>dvanced technology:</b></strong></p>
<ul>
<li>Automatic detection and filtering of fine air bubbles, waste liquid overflow alarm function</li>
<li>Key materials are imported from the United States, and the technology level is internationally leading.</li>
<li>With power-off protection function, the results can be automatically stored up to 10,000 sets of data;</li>
<li>It can be connected to the LIS system to facilitate hospital management;</li>
<li>After sample analysis, it has automatic flushing function to keep the electrode in good standby condition.</li>
</ul>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-delectrolyte-2/">Analyseur d&rsquo;électrolyte</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Specifications</strong></h2>
<table class="table-1">
<tbody>
<tr>
<td width="132">Test item</td>
<td width="454">K, Na, Cl, iCa, nCa, TCa, pH</td>
</tr>
<tr>
<td width="132">Sample Types</td>
<td width="454">Serum, Plasma, Whole blood, Cerebrospinal fluid and diluted urine</td>
</tr>
<tr>
<td width="132">Sample consumption</td>
<td width="454">150μL</td>
</tr>
<tr>
<td width="132">Measuring technology</td>
<td width="454">Ion Selective Electrode</td>
</tr>
<tr>
<td width="132">Analysis time</td>
<td width="454">40 seconds</td>
</tr>
<tr>
<td width="132">Storage</td>
<td width="454">Up to 10000 test results</td>
</tr>
<tr>
<td width="132">Printer</td>
<td width="454">Internal thermal printer</td>
</tr>
<tr>
<td width="132">Ambient Conditions</td>
<td width="454">15-40 °C (60-104 F), ≤ 85% humidity</td>
</tr>
<tr>
<td width="132">Electricity</td>
<td width="454">220V±20V AC, 50Hz-60Hz, ≤120W</td>
</tr>
<tr>
<td width="132">Dimension</td>
<td width="454">380mm*270mm*400mm</td>
</tr>
<tr>
<td width="132">Net weight</td>
<td width="454">7Kg</td>
</tr>
</tbody>
</table>
<p><strong><b>Measuring range, resolution and accuracy:</b></strong></p>
<table class="table-1">
<tbody>
<tr>
<td width="74">Items</td>
<td width="149">Measuring Range</td>
<td width="111">Resolution</td>
<td width="205">Measuring Precision (CV%)</td>
</tr>
<tr>
<td width="74">K<sup>+</sup></td>
<td width="149">0.5-20.0 mmol/L</td>
<td width="111">0.01 mmol/L</td>
<td width="205">≤1.5%</td>
</tr>
<tr>
<td width="74">Na<sup>+</sup></td>
<td width="149">30-200 mmol/L</td>
<td width="111">0.1 mmol/L</td>
<td width="205">≤1.5%</td>
</tr>
<tr>
<td width="74">Cl<sup>–</sup></td>
<td width="149">20-200 mmol/L</td>
<td width="111">0.1 mmol/L</td>
<td width="205">≤1.5%</td>
</tr>
<tr>
<td width="74">Ca<sup>2+</sup></td>
<td width="149">0.2-5.0 mmol/L</td>
<td width="111">0.01 mmol/L</td>
<td width="205">≤2.0%</td>
</tr>
<tr>
<td width="74">pH</td>
<td width="149">4-9 pH</td>
<td width="111">0.01 pH</td>
<td width="205">≤0.5%</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-delectrolyte-2/">Analyseur d&rsquo;électrolyte</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Analyseur d&#8217;électrolyte multi-fonction</title>
		<link>https://muniatech.com/produit/analyseur-delectrolyte-multi-fonction/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Mon, 26 Sep 2022 21:16:30 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3806</guid>

					<description><![CDATA[<h2><strong>Description</strong></h2>
<div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling">
<div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start">
<div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column">
<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<p><strong><b>Description</b></strong></p>
<p>The electrolyte analyzer adopts advanced all-solid-state ion-selective electrode sensor measurement technology, and the sample does not need to be centrifuged; It has large screen display, automatic screensaver, friendly interface, convenient and simple operation, is a high degree of automation, complete functions, easy operation, and is accurate and reliable clinical testing equipment.</p>
<p><strong><b>Features</b></strong></p>
<ul>
<li><b></b><strong><b>Multi- function </b></strong><strong><b>d</b></strong><strong><b>etection: </b></strong>Besides for the detection of blood gas, it also has option to test electrolyte items K+, Na+, CI-, and Ca2+, allowing for multi – function detection.</li>
<li><b></b><strong><b>Advanced </b></strong><strong><b>t</b></strong><strong><b>echnology: </b></strong>Solid electrode technology, Liquid calibration technology, Wet measurement mode, with good repeatability and high accuracy.</li>
<li><b></b><strong><b>Cost-</b></strong><strong><b>e</b></strong><strong><b>ffective: </b></strong>Cartridge type reagent package.</li>
<li><b></b><strong><b>Easy </b></strong><strong><b>o</b></strong><strong><b>peration: </b></strong>8” colorful graphical touch screen operation</li>
</ul>
</div>
</div>
</div>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-delectrolyte-multi-fonction/">Analyseur d&rsquo;électrolyte multi-fonction</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Specifications</strong></h2>
<table class="table-1">
<tbody>
<tr>
<td width="167">Measurement items</td>
<td width="248">pH, TCO<sub>2</sub>, Na<sup>+</sup>, K<sup>+</sup>, Cl<sup>–</sup>, Ca<sup>2+</sup></td>
</tr>
<tr>
<td width="167">Calculation parameters</td>
<td width="248">PCO<sub>2</sub> (TC), TCa, nCa</td>
</tr>
<tr>
<td width="167">Sample</td>
<td width="248">Whole blood 150ul</td>
</tr>
<tr>
<td width="167">Test Method</td>
<td width="248">Automatic sampling</td>
</tr>
<tr>
<td width="167">Testing time</td>
<td width="248">50s</td>
</tr>
<tr>
<td width="167">Printer</td>
<td width="248">Build-in thermal printer</td>
</tr>
<tr>
<td width="167">Display screen</td>
<td width="248">8″ TFT colorful LCD touch screen</td>
</tr>
<tr>
<td width="167">Storage</td>
<td width="248">≥5000 test results</td>
</tr>
<tr>
<td width="167">Interface</td>
<td width="248">RS232</td>
</tr>
<tr>
<td width="167">Electricity</td>
<td width="248">100V~240V, 47Hz~63Hz</td>
</tr>
</tbody>
</table>
<table class="table-1">
<tbody>
<tr>
<td width="53">Item</td>
<td width="171">Reference Range</td>
<td width="190">Linearity Range</td>
</tr>
<tr>
<td width="53">K<sup>+</sup></td>
<td width="171">3.5- 5.5 mmol/L</td>
<td width="190">1.60 – 7.50 mmol/L</td>
</tr>
<tr>
<td width="53">Na<sup>+</sup></td>
<td width="171">135- 145 mmol/L</td>
<td width="190">100 – 180 mmol/L</td>
</tr>
<tr>
<td width="53">Cl<sup>–</sup></td>
<td width="171">96 – 108 mmol/L</td>
<td width="190">85- 150 mmol/L</td>
</tr>
<tr>
<td width="53">Ca<sup>++</sup></td>
<td width="171">1.1- 1.4 mmol/L</td>
<td width="190">1.50 – 3.00 mmol/L</td>
</tr>
<tr>
<td width="53">pH</td>
<td width="171">7.35- 7.45</td>
<td width="190">3.000 – 12.0000</td>
</tr>
<tr>
<td width="53">PO<sub>2</sub></td>
<td width="171">60 – 100 mmHg</td>
<td width="190">0- 800.0 mmHg</td>
</tr>
<tr>
<td width="53">PCO<sub>2</sub></td>
<td width="171">35- 45 mmHg</td>
<td width="190">2.0-200.0 mmHg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-delectrolyte-multi-fonction/">Analyseur d&rsquo;électrolyte multi-fonction</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Analyseur d&#8217;électrolyte</title>
		<link>https://muniatech.com/produit/analyseur-delectrolyte/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Mon, 26 Sep 2022 20:54:23 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3803</guid>

					<description><![CDATA[<h2><strong>Description</strong></h2>
<p><strong><b>Description</b></strong></p>
<p>The electrolyte analyzer has self-test functions with hints to solve problem; 21,000 record storage; Automatic one-point and two-point calibration, plus manual calibration.</p>
<p><strong><b>Features</b></strong></p>
<ul>
<li>Sample type: plasma, serum, whole blood, urine.</li>
<li>Self-test functions with hints to solve problem</li>
<li>Wide LCD display（240*128）</li>
<li>Dot matrix or thermal printer on demand</li>
<li>Numeric keypad for convenient operations</li>
<li>Randomly choose any combination of K，Na，Cl，Ca，pH</li>
<li>High efficient cleaning procedures best for fatty samples</li>
<li>Automatic calibration on alarms</li>
<li>High middle and low QC values provided to adjust linearity</li>
<li>RS232 port available</li>
<li>Slope and intercept adjustable to ensure accuracy and linearity</li>
<li>Electrode maintenance alerts</li>
<li>Closed container for both calibrates and waste, which prevents the bio-organic pollution</li>
<li>Auto sampler volume:39 samples</li>
</ul>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-delectrolyte/">Analyseur d&rsquo;électrolyte</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Specifications</strong></h2>
<table class="table-1">
<tbody>
<tr>
<td colspan="4" width="557"><strong><b>Test range and accuracy</b></strong></td>
</tr>
<tr>
<td width="92">Channel</td>
<td width="204">Range</td>
<td width="132">Resolution</td>
<td width="128">CV%</td>
</tr>
<tr>
<td width="92">pH</td>
<td width="204">6.00~9.00</td>
<td width="132">0.01</td>
<td width="128">=1.0</td>
</tr>
<tr>
<td width="92">K<sup>+</sup></td>
<td width="204">0.50~10.00mmol/L</td>
<td width="132">0.01</td>
<td width="128">&lt;1.0</td>
</tr>
<tr>
<td width="92">Na<sup>+</sup></td>
<td width="204">20.0~200.0 mmol/L</td>
<td width="132">0.1</td>
<td width="128">&lt;1.0</td>
</tr>
<tr>
<td width="92">Cl<sup>–</sup></td>
<td width="204">20.0~200.0 mmol/L</td>
<td width="132">0.1</td>
<td width="128">&lt;1.0</td>
</tr>
<tr>
<td width="92">Ca<sup>++</sup></td>
<td width="204">0.3~5.0mmol/L</td>
<td width="132">0.01</td>
<td width="128">&lt;1.5</td>
</tr>
<tr>
<td width="92">Li<sup>+</sup></td>
<td width="204">0.1~30 mmol/L</td>
<td width="132">0.01</td>
<td width="128">&lt;1.5</td>
</tr>
</tbody>
</table>
<table class="table-1">
<tbody>
<tr>
<td width="189">Ambient Temperature</td>
<td width="189">5°C~40℃</td>
</tr>
<tr>
<td width="189">Relative Humidity</td>
<td width="189">85%</td>
</tr>
<tr>
<td width="189">Sun Radiation</td>
<td width="189">Avoid direct sunshine</td>
</tr>
<tr>
<td width="189">Electricity</td>
<td width="189">100-240v～50/60Hz</td>
</tr>
<tr>
<td width="189">Packing dimension</td>
<td width="189">520 * 450* 470 mm</td>
</tr>
<tr>
<td width="189">Net weight</td>
<td width="189">8.25Kg</td>
</tr>
<tr>
<td width="189">Gross weight</td>
<td width="189">10.5Kg</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-delectrolyte/">Analyseur d&rsquo;électrolyte</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
	</channel>
</rss>