<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	 xmlns:media="http://search.yahoo.com/mrss/" >

<channel>
	<title>Analyseurs d&#039;hématologie - Muniatech</title>
	<atom:link href="https://muniatech.com/categorie-produit/instruments-danalyses/analyseurs-dhematologie/feed/" rel="self" type="application/rss+xml" />
	<link>https://muniatech.com/categorie-produit/instruments-danalyses/analyseurs-dhematologie/</link>
	<description>Performance delivred</description>
	<lastBuildDate>Sun, 25 Sep 2022 13:23:17 +0000</lastBuildDate>
	<language>fr-FR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.3.5</generator>

<image>
	<url>https://muniatech.com/wp-content/uploads/2022/05/cropped-NewIcon-32x32.png</url>
	<title>Analyseurs d&#039;hématologie - Muniatech</title>
	<link>https://muniatech.com/categorie-produit/instruments-danalyses/analyseurs-dhematologie/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Analyseur des gaz du sang PCO2</title>
		<link>https://muniatech.com/produit/analyseur-des-gaz-du-sang-pco2/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 25 Sep 2022 13:23:16 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3786</guid>

					<description><![CDATA[<div class="fusion-column-wrapper fusion-flex-justify-content-flex-start fusion-content-layout-column">
<div class="fusion-text fusion-text-1">
<h2><strong><b>Features</b></strong></h2>
<ul>
<li>Intuitive touch screen: High resolution 10.4” touch screen</li>
<li>Infrared human-detector</li>
<li>Flexible and simple calibrants cartridge</li>
<li>All-in-one design without extra consumables</li>
<li>Cartridge expiration alarm and residue information</li>
<li>Auto-stop analysis sample once failing on QC</li>
</ul>
</div>
</div>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-des-gaz-du-sang-pco2/">Analyseur des gaz du sang PCO2</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Specifications</strong></h2>
<p><strong>Measured Parameters</strong></p>
<table class="table-1">
<tbody>
<tr>
<td width="189">Analyte</td>
<td width="189">Measuring range</td>
<td width="189">Unit</td>
</tr>
<tr>
<td width="189">Hydrogen ion activity(pH)</td>
<td width="189">6.000 ― 9.000</td>
<td width="189">pH scale</td>
</tr>
<tr>
<td width="189">Carbon dioxide</td>
<td width="189">0.667 ― 26.67</td>
<td width="189">kPa</td>
</tr>
<tr>
<td width="189">partial pressure(pCO2)</td>
<td width="189">5.0 ― 200.0</td>
<td width="189">mmHg</td>
</tr>
<tr>
<td rowspan="2" width="189">Oxygen partial pressure(pCO2)</td>
<td width="189">0 ― 106.7</td>
<td width="189">kPa</td>
</tr>
<tr>
<td width="189">0 ― 800.0</td>
<td width="189">mmHg</td>
</tr>
<tr>
<td width="189">Potassium ion (K+)</td>
<td width="189">0.50 ― 10.00</td>
<td width="189">mmol/L</td>
</tr>
<tr>
<td width="189">Sodium ion (Na+)</td>
<td width="189">50.0 ― 200.0</td>
<td width="189">mmol/L</td>
</tr>
<tr>
<td width="189">Chloride ion (Cl-)</td>
<td width="189">20.0 ― 200.0</td>
<td width="189">mmol/L</td>
</tr>
<tr>
<td width="189">Ionized calcium (Ca++)</td>
<td width="189">0.10 ― 5.00</td>
<td width="189">mmol/L</td>
</tr>
<tr>
<td width="189">Hct</td>
<td width="189">12.0―65.0</td>
<td width="189">%</td>
</tr>
<tr>
<td width="189">B.P.</td>
<td width="189">500 ― 800</td>
<td width="189">mmHg</td>
</tr>
<tr>
<td width="189">Glucose</td>
<td width="189">1.1 ― 66.7</td>
<td width="189">mmol/L</td>
</tr>
<tr>
<td width="189">Lactate</td>
<td width="189">0.4 ― 30.0</td>
<td width="189">mmol/L</td>
</tr>
</tbody>
</table>
<p><strong>Derived (Calculated) Parameters:</strong></p>
<table class="table-1">
<tbody>
<tr>
<td width="284">pH (TC)</td>
<td width="284">pH temperature corrected</td>
</tr>
<tr>
<td width="284">pCO<sub>2</sub> (TC)</td>
<td width="284">pCO<sub>2</sub> temperature corrected</td>
</tr>
<tr>
<td width="284">pO<sub>2</sub> (TC)</td>
<td width="284">pO<sub>2</sub> temperature corrected</td>
</tr>
<tr>
<td width="284">TCO<sub>2</sub></td>
<td width="284">0-50mmol/L</td>
</tr>
<tr>
<td width="284">HCO<sub>3</sub></td>
<td width="284">0-50mmol/L</td>
</tr>
<tr>
<td width="284">Be<sub>b</sub></td>
<td width="284">-25.0-25mmol/L</td>
</tr>
<tr>
<td width="284">Be<sub>ecf</sub></td>
<td width="284">-25.0-25mmol/L</td>
</tr>
<tr>
<td width="284">SBC</td>
<td width="284">0-50mmol/L</td>
</tr>
<tr>
<td width="284">SO<sub>2</sub>%</td>
<td width="284">40-100.0%</td>
</tr>
<tr>
<td width="284">Ca++(7.4)</td>
<td width="284">Ionized calcium “normalized” to pH 7.4</td>
</tr>
<tr>
<td width="284">TCa</td>
<td width="284">Total calcium content</td>
</tr>
<tr>
<td width="284">AG</td>
<td width="284">Anion gap</td>
</tr>
<tr>
<td width="284">RI</td>
<td width="284">0.0-70.0</td>
</tr>
<tr>
<td width="284">AaDO2</td>
<td width="284">0-700mmHg</td>
</tr>
<tr>
<td width="284">O2SAT</td>
<td width="284">Oxygen Saturation</td>
</tr>
<tr>
<td width="284">tHb(c)</td>
<td width="284">Hemoglobin (Calculated)</td>
</tr>
</tbody>
</table>
<table class="table-1">
<tbody>
<tr>
<td width="284">Sample</td>
<td width="284">Whole blood, Serum, Plasma, Dialysate, CSF</td>
</tr>
<tr>
<td width="284">Test items</td>
<td width="284">pH, pCO<sub>2</sub><sub>,</sub> pO<sub>2</sub><sub>,</sub> K<sup>+</sup><sup> </sup>, Na<sup>+</sup>, Cl<sup>–</sup> , Ca<sup>++</sup>, Hct</td>
</tr>
<tr>
<td width="284">Input parameter</td>
<td width="284">Patient temperatureHemoglobin</p>
<p>FiO</p>
<p>B.P.</td>
</tr>
<tr>
<td width="284">Interface</td>
<td width="284">Serial Line RS-232TCP/IP interface</p>
<p>USB port</p>
<p>Integrated Bar-code reader</td>
</tr>
<tr>
<td width="284">Analysis time</td>
<td width="284">&lt;90s</td>
</tr>
<tr>
<td width="284">Sample volume</td>
<td width="284">95μL Whole blood50uL Capillary blood</td>
</tr>
<tr>
<td width="284">Calibration</td>
<td width="284">Automatic， programmable 1-point and 2-point calibration</td>
</tr>
<tr>
<td width="284">Data storage</td>
<td width="284">&gt;10000</td>
</tr>
<tr>
<td width="284">Display</td>
<td width="284">10.4” TFT touch screen</td>
</tr>
<tr>
<td width="284">Battery</td>
<td width="284">Nickel-metal hydride battery 3.0Ah</td>
</tr>
<tr>
<td width="284">Printer</td>
<td width="284">Build-in Thermal printer70mm</td>
</tr>
<tr>
<td width="284">Barcode reader</td>
<td width="284">Up to 14 kinds of barcode type</td>
</tr>
<tr>
<td width="284">Instrument(W*H*D)</td>
<td width="284">400*574*344mm</td>
</tr>
<tr>
<td width="284">CAL PAK(W*H*D)</td>
<td width="284">258*180*70mm</td>
</tr>
<tr>
<td width="284">AUTOQC(W*H*D)</td>
<td width="284">103*180*70mm</td>
</tr>
<tr>
<td width="284">Weight</td>
<td width="284">18Kg</td>
</tr>
<tr>
<td width="284">Work environment</td>
<td width="284">15℃~30℃</td>
</tr>
<tr>
<td width="284">Storage environment</td>
<td width="284">5℃~40℃</td>
</tr>
<tr>
<td width="284">Electricity</td>
<td width="284">100-240V~50/60Hz</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-des-gaz-du-sang-pco2/">Analyseur des gaz du sang PCO2</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Automate d&#8217;identification bactérienne</title>
		<link>https://muniatech.com/produit/automate-didentification-bacterienne/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sun, 25 Sep 2022 13:18:12 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3789</guid>

					<description><![CDATA[<h2><strong>Features</strong></h2>
<ul>
<li>Running bacteria ID and AST at the same time and reporting the ID and AST results.</li>
<li>Identification range covering the vast majority of routine organisms (over 500 microorganisms), such as Enterobacteriaceae, non-Fermentative bacteria, bacteria of Vibrionaceae, Staphylococcus/Micrococcus, Yeast like fungi, Streptococcus, Enterococcus, Vibrionaceae, etc.</li>
<li>Advanced expert system presents testing results with high accuracy and instructive interpretation for over 200 kinds of antibiotics.</li>
<li>Test card is 96-well composite plate of identification and drug sensitivity.</li>
<li>Micro-dilution method plus turbidimetry provides S.I.R report and MIC value.</li>
<li>According to CLSI regulation, antibiotics are divided into A/B/C/U group to report MIC results, which help doctors to choose the appropriate antibiotics.</li>
<li>Multiple drug resistant monitoring: MRSA, BETA-lac, VRE, VRSA, HLAR, ESBLs</li>
</ul>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/automate-didentification-bacterienne/">Automate d&rsquo;identification bactérienne</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2><strong>Specifications</strong></h2>
<p><strong>Technical specifications</strong></p>
<table>
<tbody>
<tr>
<td>
<div>Test Principles</div>
</td>
<td>
<div>Identification: Colorimetry<br />
Susceptibility testing: Turbidimetry</div>
</td>
</tr>
<tr>
<td>
<div>Throughput</div>
</td>
<td>
<div>60 &#8211; 120 sample per hour</div>
</td>
</tr>
<tr>
<td>
<div>Optional Configuration</div>
</td>
<td>
<div>Automated sampling device, sampling 60-80 plates per hour</div>
</td>
</tr>
<tr>
<td>
<div>Working environment</div>
</td>
<td>
<div>Environmental temperature: 5ºC &#8211; 40ºC.<br />
Relative humidity: 10% &#8211; 90%.<br />
Placed on a steady and plane table, away from direct strong sun light and electromagnetic interference, and well grounded</div>
</td>
</tr>
<tr>
<td>
<div>
<div>Atmospheric pressure</div>
</div>
</td>
<td>
<div>76kPa &#8211; 106kPa.</div>
</td>
</tr>
<tr>
<td>
<div>Power supply</div>
</td>
<td>
<div>AC 110-240V, 50/60 HZ</div>
</td>
</tr>
<tr>
<td>
<div>Dimension &amp; Weigh</div>
</td>
<td>
<div>700mm * 493 mm * 465 mm; 31.2 kg</div>
</td>
</tr>
</tbody>
</table>
<p><strong>Combo ID/AST Card</strong></p>
<table>
<tbody>
<tr>
<td>
<div>
<div>Test Card</div>
</div>
</td>
<td>
<div>
<div>Identification Range</div>
</div>
</td>
<td>
<div>
<div>Package</div>
</div>
</td>
</tr>
<tr>
<td>
<div>
<div>DL-96 FUNGUS</div>
</div>
</td>
<td>
<div>
<div>Fungi</div>
</div>
</td>
<td>
<div>
<div>10 Cassette +Accessory Medium</div>
</div>
</td>
</tr>
<tr>
<td>
<div>
<div>DL-96 STAPH</div>
</div>
</td>
<td>
<div>
<div>Cocci</div>
</div>
</td>
<td>
<div>
<div>10 Cassette +Accessory Medium</div>
</div>
</td>
</tr>
<tr>
<td>
<div>
<div>DL-96 STREP</div>
</div>
</td>
<td>
<div>
<div>Streptococcus</div>
</div>
</td>
<td>
<div>
<div>10 Cassette +Accessory Medium</div>
</div>
</td>
</tr>
<tr>
<td>
<div>
<div>DL-96 NE</div>
</div>
</td>
<td>
<div>
<div>Non-fermentative bacteria</div>
</div>
</td>
<td>
<div>
<div>10 Cassette +Accessory Medium</div>
</div>
</td>
</tr>
<tr>
<td>
<div>
<div>DL-96 E</div>
</div>
</td>
<td>
<div>
<div>Enterobacteriaceae</div>
</div>
</td>
<td>
<div>
<div>10 Cassette +Accessory Medium</div>
</div>
</td>
</tr>
</tbody>
</table>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/automate-didentification-bacterienne/">Automate d&rsquo;identification bactérienne</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
		<item>
		<title>Analyseur automatique d&#8217;hématologie</title>
		<link>https://muniatech.com/produit/analyseur-automatique-dhematologie/</link>
		
		<dc:creator><![CDATA[franck ekangoh]]></dc:creator>
		<pubDate>Sat, 24 Sep 2022 20:15:37 +0000</pubDate>
				<guid isPermaLink="false">https://muniatech.com/?post_type=product&#038;p=3745</guid>

					<description><![CDATA[<h2>Feature</h2>
<ul>
<li>Throughput 60T/H.</li>
<li>14-inch touch screen.</li>
<li>Tri-angle laser scatter + flow cytometry method + impedance method for RBC and PLT counting.</li>
<li>3D holographic scattergram displays the accurate 5-part differentiation of WBC.</li>
<li>Large storage capacity: 100,000 results (including histogram, scattergram, patient information).</li>
</ul>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-automatique-dhematologie/">Analyseur automatique d&rsquo;hématologie</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></description>
										<content:encoded><![CDATA[<h2>Specification</h2>
<table style="height: 1337px;" border="1" width="977" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td>Throughput</td>
<td colspan="4">60Tests/hour</td>
</tr>
<tr>
<td>Assay Items</td>
<td colspan="4">5 parts, 29parameters,3 histograms</td>
</tr>
<tr>
<td>Principle</td>
<td colspan="4">Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, Impedance method for RBC and PLT counting, Cyanide-free method for HGB test</td>
</tr>
<tr>
<td>Test Mode</td>
<td colspan="4">CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted.</td>
</tr>
<tr>
<td>Parameters</td>
<td colspan="4">WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#</p>
<p>4 Research parameter: ALY%, ALY#, IG%, IG#</td>
</tr>
<tr>
<td rowspan="5">Performance</td>
<td>Item</td>
<td>Linearity Range</td>
<td>Carry Over</td>
<td>CV</td>
</tr>
<tr>
<td>WBC</td>
<td>(0~300.0&#215;10^9)/L</td>
<td>≤0.5%</td>
<td>≤2.0%</td>
</tr>
<tr>
<td>RBC</td>
<td>(0~8.00&#215;10^12)/L</td>
<td>≤0.5%</td>
<td>≤1.5%</td>
</tr>
<tr>
<td>HGB</td>
<td>(0~250) g/L</td>
<td>≤0.5%</td>
<td>≤1.5%</td>
</tr>
<tr>
<td>PLT</td>
<td>(0~3000&#215;10^9)/L</td>
<td>≤1.0%</td>
<td>≤4.0%</td>
</tr>
<tr>
<td>Sample Volume</td>
<td colspan="4">CBC+DIFF mode≤20μl   CBC mode≤10μl</td>
</tr>
<tr>
<td>Storage</td>
<td colspan="4">10,000 results including histograms, scattergrams and patient information</td>
</tr>
<tr>
<td>Interface</td>
<td colspan="4">4 USB ports, 1LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader</td>
</tr>
<tr>
<td>Power Supply</td>
<td colspan="4">AC220V±10% 50/60Hz; 110V±10% 60Hz; 400VA</td>
</tr>
<tr>
<td>Package Size</td>
<td colspan="4">670*590*790mm(W*D*H)</td>
</tr>
<tr>
<td>Gross Weight</td>
<td colspan="4">53kg</td>
</tr>
<tr>
<td>Reagent Package Size</td>
<td colspan="4">320*320*290mm (W*D*H)</td>
</tr>
<tr>
<td>Reagent Gross Weight</td>
<td colspan="4">22kg</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>L’article <a rel="nofollow" href="https://muniatech.com/produit/analyseur-automatique-dhematologie/">Analyseur automatique d&rsquo;hématologie</a> est apparu en premier sur <a rel="nofollow" href="https://muniatech.com">Muniatech</a>.</p>
]]></content:encoded>
					
		
		
		
	</item>
	</channel>
</rss>
